BKQBM - TEFLON TOPCOATS, 455-1123
- MSDS: BKQBM
- Manufacturer: E I DUPONT DE NEMOURS AND CO
- Product Name: TEFLON TOPCOATS, 455-1123
- National Stock Number: 8010-00N015357
Product Identification
Product ID:TEFLON TOPCOATS, 455-1123
MSDS Date:01/01/1987
FSC:8010
NIIN:00N015357
MSDS Number: BKQBM
Responsible Party
WILMINGTON, DE 19898
US
Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)
Info Phone: 800-441-7515
Cage: 0ERJ7
Contractor
Telephone: 800-441-7515;800-441-9442
Cage: 18873
Ingredients
C-ACGIH). HIGH CONC CAN CAUSE LUNG DMG, PULM
RTECS: 9999999ZZ
TO DMG BY HF & ATTN MUST BE GIVEN TO EXHAUST
RTECS: 9999999ZZ
FLUOROPOLYMER SOLIDS
0.01.
CAS: 112-34-5
RTECS: KJ9100000
0.01
CAS: 102-71-6
RTECS: KL9275000
5
CAS: 64742-95-6
OCTYLPHENOXYPOLYETHOXYETHANOL (NON-IONIC SURFACTANT)
IRON OXIDE
CAS: 1309-37-1
RTECS: NO7400000
OSHA PEL 10 MG/M3 (FE)
ACGIH TLV: 5 MG/M3(FE),B2; 9293
CARBON BLACK
CAS: 1333-86-4
RTECS: FF5800000
OSHA PEL 3.5 MG/M3
ACGIH TLV: 3.5 MG/M3; 9192
CONSCIOUSNESS. CAUSES EYE CORR & PERM
RTECS: 9999999ZZ
IRRIT. RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN IRRIT &
RTECS: 9999999ZZ
NAUS & LOSS OF CONSCIOUSNESS. RPTS HAVE ASSOC RPTD &
RTECS: 9999999ZZ
DMG. (ING 5) CONT MAY CAUSE SKIN IRRIT
RTECS: 9999999ZZ
CAUSE IRRIT OF MUC MEMB. (ING 7) NO KNOWN HAZARD
RTECS: 9999999ZZ
BAKING OVENS MUST BE PROPERLY VENT. AT TEMPS ABOVE
RTECS: 9999999ZZ
EVOLVED; AMTS INCR AS TEMPS INCR. HYDROGEN FLUORIDE
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: NORMALLY NOT A HAZ. THESE PRODS
CONTAIN SM AMTS OF SOLV AS DESCRIBED BELOW. SKIN/EYE: MAY CAUSE
IRRIT/BURNING OF EYES. RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN IRRIT
W/DISCOMFORT & DERMAT. OTHER POT ENTIAL HAZ INCL: (ING 1) SEE HAZ
DECOMPPRODS. (ING 2) MAY CAUSE EYE IRRIT W/DISCOMFORT, TEARING (SEE
EFTS OF OVEREXP)
Explanation of Carcinogenicity:NONE.
Effects of Overexposure:HLTH HAZ: OR BLURRED VISION. CONT MAY CAUSE
SKIN IRRIT W/DISCOMFORT/RASH. CAN BE ABSORBED THRU SKIN IN HARMFUL
AMTS. MAY CAUSE ABNORMAL KIDNEY FUNC. (ING 3) OVEREXP MAY CAUSE
EYE, NOSE & THROAT IRRIT. RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN
IRRIT & DERMAT. MAY CAUSE CNS EFTS SUCH AS DIZZ, HDCH, NAUS, & LOSS
OF (SEE ING 8)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL: IF AFFECTED BY INHAL OF VAP/SPRAY MIST, REMOVE TO
FRESH AIR. IF NOT BRTHG, GIVE ARTF RESP, PREF MOUTH-TO-MOUTH. IF
BRTHG DIFFICULTY PERSISTS/OCCUR LATER, CALL MD. SKIN/EYE: EYE:
IMMED FLUSH W/P LENTY OF WATER FOR AT LEAST 15 MIN; CALL MD. SKIN:
WASH W/SOAP & WATER. IF IRRIT OCCURS, CALL MD. INGEST: GI DISTRESS.
IN UNLIKELY EVENT OF INGEST, CALL MD IMMED & HAVE NAMES OF INGRED
AVAIL.
Fire Fighting
Flash Point:NONE
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL PROT
EQUIP . WATER FROM FOG NOZZLES MAY BE USED TO COOL CLOSED
CONTAINERS TO PREVENT PRESSURE BUILD-UP.
Unusual Fire/Explosion Hazard:HYDROGEN FLUORIDE IS RELEASED DURING A
FIRE.
Accidental Release
Spill Release Procedures:VENT AREA. REMOVE SOURCES OF IGNITION. AVOID
SKIN CONTACT AND BREATHING OF VAPOR. CONFINE AND REMOVE WITH INERT
ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:OBSERVE LABEL PREC. KEEP AWAY FROM
HEAT, SPARKS & FLAME. CLOSE CNTNR AFTER EACH USE. GROUND CNTNRS
WHEN POURING. DO NOT STORE ABOVE 120F.
Other Precautions:EXPLOS RXN MAY OCCUR ABOVE 796F W/FINELY DIVIDED
FLUOROCARBON AND METAL POWDER (ALUMINUM/MAGNESIUM). OPERATIONS SUCH
AS GRINDING, BUFFING OR GRIT BLASTING MAY GENERATE SUCH MIXTURES.
KEEP WET. USE ADE QUATE VENT TO CONTROL.
Exposure Controls
Respiratory Protection:DO NOT BREATHE VAPS/MISTS. WEAR A PROPERLY
FITTED NIOSH/MSHA APPROVED VAPOR/PARTICULATE RESP FOR USE WITH
PAINTS DURING APPLICATN & UNTIL ALL VAPS & SPRAY MIST ARE
EXHAUSTED. FOLLOW RESP MFR DIRECTION S FOR RESP USE.
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME & PATTERN TO KEEP
CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEM WORKERS GOGG.MAY ADD(SEE INGRED-17)
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING AND SMOKING.
Supplemental Safety and Health
% VOLAT: 46.3-49.1 (WT). HAZ DECOMP PRODS: THESE SYMP DO NOT ORDINARILY
OCCUR UNTIL SEV HRS AFTER EXPOS & PASS WITHIN 36-48 HRS. EFTS ARE
NOT CUMULATIVE. EXPOS USUALLY RESULTS FROM SMOKING TOBACCO/CIG
ARETTES CONTAM W/FLUOROCARBON DURING HANDLING/FROM BRTHG VAPS
EMITTED DURING BAKING. DO NOT EXCEED REC (SEE ING 12)
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:APPRECIABLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:EXPOS TO TEFLON DECOMP PRODS CAN
CREATE INFLUENZA-LIKE SYMP, COMMONLY REFERRED TO AS POLYMER FUME
FEVER. (SEE SUPP DATA)
Disposal
Waste Disposal Methods:DO NOT ALLOW MATL TO CONTAMINATE GROUND WATER
SYSTEMS. SEND TO HAZ WASTE WATER TREATMENT PLANT/INCINERATE
ABSORBED MATL IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
REQUIREMENTS. DO NOT INCINERATE IN C LOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.